Transformers

The in-lite system operates at 12 volts (low voltage). This means that the 230 volts of power from the socket is converted to 12 volts by a transformer. This is a safe voltage, making in-lite lighting easy to connect and reposition by the consumer.

 

4Items

4Items

HUB-75 & SMART HUB-75

The HUB-75 and SMART HUB-75 are the standard transformers in our range. Both transformers can handle 75 VA, distributed over two cable outputs. Note: only the SMART HUB-75 can be controlled via the in-lite App; on the HUB-75, the outputs cannot be switched independently.

More HUB-75
SMART HUB-150

The SMART HUB-150 is operated using the in-lite app. You can connect up to 150VA in fixtures to the transformer, divided over three cable outlets if desired, each of which can be operated separately.

More SMART HUB-150

Protect your transformer

We recommend installing your SMART HUB-150, HUB-75 or SMART HUB-75 in a covered location. If this isn’t possible, use a PROTECTOR to shield your transformer from all forms of precipitation. Our PROTECTORs are made of high-quality plastic and can withstand any weather conditions.

 
HUB protector - in-lite
  HUB-75   SMART HUB-75 SMART HUB-150 SMART HUB-300
Max. connection value 75 VA   75V A 150 VA 300 VA
Control Buttons   App App App
Cable outlets 2 lines   2 lines 3 lines 3 lines
Max. connection value per cable outlet 75 VA   75 VA 100 VA 130 VA
Cables can be controlled separately ×    √  √  √
Suitable for Smart fixtures ×    √  √  √
Suitable for home Automation systems ×    √  √  √
Max. cable length 14/2 40 m   40 m 40 m ×
Max. cable length 10/2 80 m   80 m 80 m 160 m

 

  HUB-75 SMART HUB-75 SMART HUB-150 SMART HUB-300
Max. connection value 75 VA 75 VA 150 VA 300 VA
Control Buttons App App App
Cable outlets 2 lines 2 lines 3 lines 3 lines
Max. connection value per cable outlet 75 VA 75 VA 100 VA 130 VA
Cables can be controlled separately ×
Suitable for Smart fixtures ×
Suitable for home automation systems ×
Max. cable length 14/2 40 m 40 m 40 m ×
Max. cable length 10/2 80 m 80 m 80 m 160 m
  HUB-50 HUB-100 SMART HUB-150
Max. permitted voltage 50 VA 100 VA 150 VA
Operation method Touchscreen Touchscreen in-lite app
No. of ground cables (lines) 2 lines 2 lines 3 lines
Separate line operation × ×
Manual on/off √ (d.m.v. in-lite app)
Day/night switch √ (light sensor) √ (light sensor) √ (astronomical clock)
Timer function √ (hours on) √ (hours on) √ (minutes on)
Motion detector MOVE (wired) MOVE (wired) SMART MOVE (wireless)
Overload short circuit notification
Installation outdoor possible √ at >50cm √ at >50cm √ at >50cm

 

Back to top